Magnetic Pulser

Use as part of the Becks protocol 

 

What does it do?

Damages the micro-organisms that hide deeper in the tissues and cannot be affected by the Beck's Zapper. Typically these sites are the lymph nodes, but can be other areas where blood supplies are not good. This poor circulation can even be caused by some micro-organisms themselves.

This device should be used by all HIV patients about once in every three months. This is also recommended for people who have an immune dysfunction disease.

How does it work?

This device emits a strong magnetic pulse into the tissues to a depth of about 4 inches. This induces micro currents within the tissues and damages the external surfaces of micro organisms. This helps to disable them, so your immune system can overcome them in the same way as it does with the Beck's Zapper.

What does it feel like?

Each time the magnetic head emits a pulse of power the device makes a clicking sound and there is a slight sensation in the tissue beneath the device. It is not painful or uncomfortable in any way.

 

What is "The Magnetic Pulser"?

The Magnetic Pulser is a professionally designed quality unit, thoroughly tested and guaranteed to operate as per the specifications. The Magnetic Pulser (MPG) is designed to generate an intense (~43,133 Gauss*), momentary (~2.5mS) pulsed DC magnetic field.

*This 43,133 Gauss measurement is at the inter-coil winding flux. Magnetic flux intensity follows the inverse square rule - the further you are away from the magnetic core, the faster the Gauss intensity drops off. At face of Magnetic Coil, the Gauss drops to ~6,000 Gauss.

NOTE: Please do not confuse this unit with permanent/ceramic magnet therapies, or with the EMR (electro-magnetic radiation) producing units!

New Features of model MPG5:

Unique Features:

 

The Unit:

 
Line drawing of the MPG unit

 

The Magnetic Pulser is housed in a new custom plastic enclosure. A pushbutton turns the Magnetic Pulser on and off. A series of Green lights indicates power is available and visually shows unit is charging. When turned on, the Magnetic Pulser will immediately begin to charge up. When fully charged, the stored energy of the capacitor is discharged into the pulsing coil. The Red light will flash indicating the charge has been released. The Magnetic Pulser will then begin another charge cycle.

Should an overload or fault condition occur in the charging section, the MPG5 will shutdown until the fault condition is removed. The unit will beep and flash the Red light notifying the user.

After approximately 20 minutes of pulsing the MPG5 will turn itself off. This helps prevent continuous operation should the MPG5 be left on unattended.

The Magnetic Pulser is packaged in a soft carrying case for easy storage.
 

 
Line drawing of the MPG unit

Electronics:

 

The Magnetic Pulser is designed to the highest standards. We have improved on the original design with added features. Our electronic design is unique and efficient making the unit very reliable and powerful. Early designs required the use of a Xenon flashtube. We've completely re-designed The Magnetic Pulser from the ground up using the latest in electronic components. The result is a very powerful, reliable, rugged unit that transfers more energy to the output coil. In addition, we use double-insulation techniques to ensure the greatest in electrical safety. This is of extreme importance!

Specifications (as measured on a Tektronics TDS 210 Digital Real-Time Oscilloscope, and Wavetek AD105 Clamp-On RMS Ammeter)

  • Energy Storage Capacitor: 600uF, 450 Volts DC
  • Typical Energy Storage: 36.75 Joules (Watt*Seconds)
  • Maximum Energy Storage: 42.18 Joules (Watt*Seconds)
  • Typical Peak Charge Voltage: 350 Volts DC
  • Maximum Peak Charge Voltage: 375 Volts DC
  • Minimum Peak Current Discharge into Coil: 150 Amps RMS
  • Pulse Rise Time: <1.8 uS (microseconds)
  • Pulse Duration: ~2.5mS (milliseconds)
  • Main Coil Inductance: ~2.5mH (milli-henries)
  • Flux Density: 40,500 Ampere*Turns
  • *This 43,133 Gauss measurement is at the inter-coil winding flux. Magnetic flux intensity follows the inverse square rule - the further you are away from the magnetic core, the faster the Gauss intensity drops off. At face of Magnetic Coil, the Gauss drops to ~6,000 Gauss.
  • Minimum number of Pulse Discharges 30 Million (30,000,000)

Each Magnetic Pulser comes complete with:

 


 

International Voltage (220/240 Volt AC 50 Hz Mains) Requirements:

 


Options for Powering the Magnetic Pulser

In the event of a power outage here are some options for powering the Magnetic Pulser:

  1. The Magnetic Pulser may be operated directly from a 12 Volt DC Battery like an automobile cigarette lighter. You will need to purchase an Adapter cord which plugs into the cigarette lighter and has a Centre Positive, 2.1mm Plug, like from Radio Shack®.
  2. The Magnetic Pulser can be powered by a suitable solar panel. Keep in mind that most solar panel generators are used to re-charge a battery which in turn operates the unit. Therefore we suggest you use a solar panel (preferably a sealed Gel-Cel® type) to re-charge a 12 Volt DC automobile battery, then run the Magnetic Pulser directly from the battery. You will need to use a cord which has alligator clips on one end to attach to the battery terminals, and the appropriate Centre Positive, 2.1mm Plug on the other end to plug into the Magnetic Pulser. Be careful with polarity! This type of cord with alligator clips on one end is probably not readily available, therefore you will to need to buy a cord and cut off the end that normally goes into the cigarette lighter, and solder your own set of alligator clips. Use a black and red alligator clips so you ensure polarity is correct each time you connect the circuit.
  3. If you wish to operate the Magnetic Pulser directly from a solar panel you will need to use a 12 Volt DC output panel that is capable of supplying at least 2.5 Amps. The Magnetic Pulser's initial starting demands may require a higher output solar panel. That is why it is preferable to use a charged 12 Volt DC battery instead.